Troubleshooting Haitian injection molding machine error: no heating signal in section 4.

1. Remove and inspect the control board.

  • Open the electrical cabinet: Open the protective box and disconnect the signal connectors attached to the AK668 (or equivalent) circuit board.

  • Cleaning: Use a brush and compressed air to remove dust and dirt from the circuit board before in-depth testing.

2. Circuit board repair process

  • Identify the faulty component: Measure and test the output signal control system for heating section 4. The fault is usually in the small signal switching components on the circuit.

  • Replacing components: * Use a heat gun and soldering iron to remove the damaged component.

    • Clean the solder joints thoroughly using flux or specialized circuit cleaning fluid.

    • Solder the new components into the correct positions, ensuring a secure solder joint with no short circuits.

3. Install and reconnect.

  • Installing the circuit board: Place the circuit board back in its original position and tighten the retaining screws.

  • Wiring: Reconnect all signal jacks. Pay particular attention to checking the heating control signal wires (section 4) to ensure good contact.

4. Operational testing

  • Turn on the machine and observe the display on the control panel.

  • Check the signal output status at the heating page. If the error has been corrected, the temperature of section 4 will begin to rise and display a normal operating status.

Repairing circuit boards requires precise soldering skills. If you are not confident, you should contact the technical department for professional replacement or repair assistance.