1. Troubleshooting: The push button is not fully retracted.
-
Problem: The machine displays a pin position error during the mold closing operation. Observation shows that the ejector pin has not retracted to its final position.
-
Solution: * Switch to mold adjustment mode, press the button to roll back all the way.
-
Reset the value (Set Zero): Access the F3 (Adjustment) page via the F10 key, enter the password 66 , move to the speaker position section and enter the value 1 to confirm setting it to 0.
-
2. Troubleshooting when the measuring scale jumps to erratic positions.
-
Check the connection: You need to check the connector on the measuring device and the wires leading to the motherboard.
-
Check the voltage signal: The return signal of the probe is located at contact AD3 on the circuit board. The standard voltage ranges from 0 to 10V depending on the actual location of the push rod.
3. Assess component damage
-
Case 1: If the returned voltage does not correspond to the actual position of the probe, determine that the probe is faulty and needs to be replaced.
-
Case 2: If the voltage is correct but the control panel still displays an incorrect value, the fault lies with the motherboard or software, and the user should contact the manufacturer for expert support.
This process helps operators quickly distinguish between common installation errors and hardware failures, allowing for timely corrective action.